Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 229
Filtrar
1.
J Diabetes Sci Technol ; : 19322968241242803, 2024 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-38613227

RESUMO

BACKGROUND: CamAPS HX fully closed-loop (FCL) system, with no user input required at mealtimes, has been shown to be safe and effective in adults with type 1 and type 2 diabetes. We assessed whether time spent in hypoglycemia and hyperglycemia during FCL insulin delivery in adults varied by type of diabetes over the 24-hour period. METHODS: We retrospectively analyzed eight weeks of data from 52 participants (adults with type 1 diabetes and adults with insulin-treated type 2 diabetes) recruited to two single-center randomized controlled studies using FCL insulin delivery during unrestricted-living conditions. Key outcomes were time spent in hypoglycemia <70 mg/dL and marked hyperglycemia >300 mg/dL by type of diabetes. RESULTS: The median percentage of time spent in hypoglycemia <70 mg/dL over the 24-hour period was lower for those with type 2 diabetes than for those with type 1 diabetes (median [interquartile range (IQR)] 0.43% [0.20-0.77] vs 0.86%, [0.54-1.46]; mean difference 0.46 percentage points [95% CI 0.23-0.70]; P < .001). Median percentage time in marked hyperglycemia >300 mg/dL was lower for those with type 2 diabetes than for those with type 1 diabetes (median [IQR] 1.8% [0.6-3.5] vs 9.3% [6.9-11.8]; mean difference 7.8 percentage points [95% CI 5.5-10.0]; P < .001). CONCLUSIONS: Using the FCL system, hypoglycemia and marked hyperglycemia exposure were lower in type 2 diabetes than in type 1 diabetes.

3.
Diabetes Technol Ther ; 26(3): 198-202, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38444312

RESUMO

The presence of diabetic ketoacidosis (DKA) at diagnosis of type 1 diabetes (T1D) is associated with higher glycated hemoglobin levels over time. We evaluated whether hybrid-closed loop (HCL) therapy from onset of T1D could prevent the adverse impact of DKA at diagnosis on long-term glycemic outcomes. This was a posthoc analysis from 51 adolescents using HCL from diagnosis of T1D as part of the CLOuD trial (NCT02871089). We compared glycemic and insulin metrics between adolescents with (n = 17) and without (n = 34) DKA at diagnosis. Participants with and without DKA at diagnosis had similar time in target glucose range 3.9-10.0 mmol/L (70-180 mg/dL), time below range (<3.9 mmol/L, <70 mg/dL) and HbA1c at 6, 12, and 24 months. While insulin requirements at 6 months were higher in those with DKA at diagnosis, this was not statistically significant after adjusting for bodyweight. Residual C-peptide secretion was similar between groups. We conclude that HCL therapy may mitigate against the negative glycemic effects of DKA at T1D diagnosis.


Assuntos
Diabetes Mellitus Tipo 1 , Cetoacidose Diabética , Adolescente , Humanos , Insulina/uso terapêutico , Diabetes Mellitus Tipo 1/complicações , Diabetes Mellitus Tipo 1/tratamento farmacológico , Cetoacidose Diabética/etiologia , Glicemia , Sistemas de Infusão de Insulina , Insulina Regular Humana
4.
J Diabetes Sci Technol ; : 19322968241231950, 2024 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-38494876

RESUMO

BACKGROUND/OBJECTIVE: The main objective of this study is to evaluate the incremental cost-effectiveness (ICER) of the Cambridge hybrid closed-loop automated insulin delivery (AID) algorithm versus usual care for children and adolescents with type 1 diabetes (T1D). METHODS: This multicenter, binational, parallel-controlled trial randomized 133 insulin pump using participants aged 6 to 18 years to either AID (n = 65) or usual care (n = 68) for 6 months. Both within-trial and lifetime cost-effectiveness were analyzed. Analysis focused on the treatment subgroup (n = 21) who received the much more reliable CamAPS FX hardware iteration and their contemporaneous control group (n = 24). Lifetime complications and costs were simulated via an updated Sheffield T1D policy model. RESULTS: Within-trial, both groups had indistinguishable and statistically unchanged health-related quality of life, and statistically similar hypoglycemia, severe hypoglycemia, and diabetic ketoacidosis (DKA) event rates. Total health care utilization was higher in the treatment group. Both the overall treatment group and CamAPS FX subgroup exhibited improved HbA1C (-0.32%, 95% CI: -0.59 to -0.04; P = .02, and -1.05%, 95% CI: -1.43 to -0.67; P < .001, respectively). Modeling projected increased expected lifespan of 5.36 years and discounted quality-adjusted life years (QALYs) of 1.16 (U.K. tariffs) and 1.52 (U.S. tariffs) in the CamAPS FX subgroup. Estimated ICERs for the subgroup were £19 324/QALY (United Kingdom) and -$3917/QALY (United States). For subgroup patients already using continuous glucose monitors (CGM), ICERs were £10 096/QALY (United Kingdom) and -$33 616/QALY (United States). Probabilistic sensitivity analysis generated mean ICERs of £19 342/QALY (95% CI: £15 903/QALY to £22 929/QALY) (United Kingdom) and -$28 283/QALY (95% CI: -$59 607/QALY to $1858/QALY) (United States). CONCLUSIONS: For children and adolescents with T1D on insulin pump therapy, AID using the Cambridge algorithm appears cost-effective below a £20 000/QALY threshold (United Kingdom) and cost saving (United States).

5.
Diabetes Technol Ther ; 26(4): 211-221, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38426909

RESUMO

Introduction: The Closing the Loop in Adults With Type 1 Diabetes (CLEAR) randomized crossover study compared a novel fully closed-loop insulin delivery system with no carbohydrate entry or mealtime bolusing (CamAPS HX), with standard insulin pump therapy and glucose sensor in adults with type 1 diabetes and suboptimal glycemic outcomes. This qualitative substudy aimed to understand the psychosocial impact of using the fully automated system. Materials and Methods: Adults participating in the CLEAR study were invited to take part in a virtual semistructured interview after they had completed 8 weeks using the fully closed-loop system. Recruitment continued until there was adequate representation and data saturation occurred. Interviews were anonymized and transcribed for in-depth thematic analysis using an inductive-deductive approach. Study participants were also asked to complete questionnaires assessing diabetes distress, hypoglycemia confidence, and closed-loop treatment satisfaction. Results: Eleven participants (eight male and three female; age range 26-66 years) were interviewed. After an initial adjustment period, interviewees reported enjoying a reduction in diabetes burden, freed-up mental capacity, and improved mood. All were happy with overnight glycemic outcomes, with the majority reporting benefits on sleep. Although experiences of postprandial glucose outcomes varied, all found mealtimes easier and less stressful, particularly when eating out. Negatives raised by participants predominantly related to the insulin pump hardware, but some also reported increased snacking and challenges around resuming carbohydrate counting at trial closeout. Conclusions: In adults with type 1 diabetes, use of a fully closed-loop insulin delivery system had significant quality-of-life benefits and provided a welcome break from the day-to-day demands of living with diabetes. Clinical Trial Registration: NCT04977908.


Assuntos
Diabetes Mellitus Tipo 1 , Insulina , Adulto , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Insulina/uso terapêutico , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/psicologia , Glicemia , Hipoglicemiantes/uso terapêutico , Estudos Cross-Over , Resultado do Tratamento , Sistemas de Infusão de Insulina , Insulina Regular Humana/uso terapêutico
6.
Artigo em Inglês | MEDLINE | ID: mdl-38315506

RESUMO

Objective: To evaluate postprandial glucose control when applying (1) faster-acting insulin aspart (Fiasp) compared to insulin aspart and (2) ultra-rapid insulin lispro (Lyumjev) compared to insulin lispro using the CamAPS FX hybrid closed-loop algorithm. Research Design and Methods: We undertook a secondary analysis of postprandial glucose excursions from two double-blind, randomized, crossover hybrid closed-loop studies contrasting Fiasp to standard insulin aspart, and Lyumjev to standard insulin lispro. Endpoints included incremental area under curve (iAUC)-2h, iAUC-4h, 4 h postprandial time in target range, time above range, and time below range. It was approved by independent research ethics committees. Results: Two trials with 8 weeks of data from 51 adults with type 1 diabetes were analyzed and 7137 eligible meals were included. During Lyumjev compared with insulin lispro, iAUC-2h and iAUC-4h were significantly decreased following breakfast (mean difference 92 mmol/L per 2 h (95% confidence interval [CI]: 56 to 127); P < 0.001 and 151 mmol/L per 4 h (95% CI: 74 to 229); P < 0.001, respectively) and the evening meal (P < 0.001 and P = 0.011, respectively). Mean time in target range (3.9-10.0 mmol/L) for 4 h postprandially significantly increased during Lyumjev with a mean difference of 6.7 percentage points (95% CI: 3.3 to 10) and 5.7 percentage points (95% CI: 1.4 to 9.9) for breakfast and evening meal, respectively. In contrast, there were no significant differences in iAUC-2h, iAUC-4h, and the other measures of postprandial glucose control between insulin aspart and Fiasp during breakfast, lunch, and evening meal (P > 0.05). Conclusion: The use of Lyumjev with CamAPS FX closed-loop system improved postprandial glucose excursions compared with insulin lispro, while the use of Fiasp did not provide any advantage compared with insulin aspart. Clinical Trial Registration numbers: NCT04055480, NCT05257460.

8.
Diabetes Technol Ther ; 25(12): 856-863, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37823892

RESUMO

Introduction: To evaluate hybrid closed-loop with ultra-rapid insulin lispro (Lyumjev) compared with hybrid closed-loop with standard insulin lispro in adults with type 1 diabetes. Materials and Methods: In a single-center, double-blind, randomized, crossover study, 28 adults with type 1 diabetes (mean ± standard deviation [SD]: age 44.5 ± 10.7 years, glycated hemoglobin (HbA1c) 7.1 ± 0.9% [54 ± 10 mmol/mol]) underwent two 8-week periods comparing hybrid closed-loop with ultra-rapid insulin lispro and hybrid closed-loop with standard insulin lispro in random order. The same CamAPS FX closed-loop algorithm was used in both periods. Results: In an intention-to-treat analysis, the proportion of time sensor glucose was in target range (3.9-10 mmol/L [70-180 mg/dL]; primary endpoint) was greater with ultra-rapid lispro compared with standard insulin lispro (mean ± SD: 78.7 ± 9.8% vs. 76.2 ± 9.6%; mean difference 2.5 percentage points [95% confidence interval 0.8 to 4.2]; P = 0.005). Mean sensor glucose was lower with ultra-rapid lispro compared with standard insulin lispro (7.9 ± 0.8 mmol/L [142 ± 14 mg/dL] vs. 8.1 ± 0.9 mmol/L [146 ± 16 mg/dL]; P = 0.048). The proportion of time with sensor glucose <3.9 mmol/L [70 mg/dL] was similar between interventions (median [interquartile range] ultra-rapid lispro 2.3% [1.3%-2.7%] vs. standard insulin lispro 2.1% [1.4%-3.3%]; P = 0.33). No severe hypoglycemia or ketoacidosis occurred. Conclusions: The use of ultra-rapid lispro with CamAPS FX hybrid closed-loop increases time in range and reduces mean glucose with no difference in hypoglycemia compared with standard insulin lispro in adults with type 1 diabetes. ClinicalTrials.gov: Trial registration number NCT05257460.


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Humanos , Adulto , Pessoa de Meia-Idade , Diabetes Mellitus Tipo 1/tratamento farmacológico , Insulina Lispro/uso terapêutico , Hipoglicemiantes/uso terapêutico , Estudos Cross-Over , Insulina/uso terapêutico , Glicemia , Sistemas de Infusão de Insulina , Hipoglicemia/tratamento farmacológico , Glucose
9.
Diabetes Technol Ther ; 25(12): 845-855, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37795883

RESUMO

Introduction: Recent high-profile calls have emphasized that women's experiences should be considered in maternity care provisioning. We explored women's experiences of using closed-loop during type 1 diabetes (T1D) pregnancy to inform decision-making about antenatal rollout and guidance and support given to future users. Methods: We interviewed 23 closed-loop participants in the Automated insulin Delivery Among Pregnant women with T1D (AiDAPT) trial after randomization to closed-loop and ∼20 weeks later. Data were analyzed thematically. Results: Women described how closed-loop lessened the physical and mental demands of diabetes management, enabling them to feel more normal and sleep better. By virtue of spending increased time-in-range, women also worried less about risks to their baby and being judged negatively by health care professionals. Most noted that intensive input and support during early pregnancy had been crucial to adjusting to, and developing confidence in, the technology. Women emphasized that attaining pregnancy glucose targets still required ongoing effort from themselves and the health care team. Women described needing education to help them determine when, and how, to intervene and when to allow the closed-loop to operate without interference. All women reported more enjoyable pregnancy experiences as a result of using closed-loop; some also noted being able to remain longer in paid employment. Conclusions: Study findings endorse closed-loop use in T1D pregnancy by highlighting how the technology can facilitate positive pregnancy experiences. To realize fully the benefits of closed-loop, pregnant women would benefit from initial intensive oversight and support together with closed-loop specific education and training. Clinical Trial Registration number: NCT04938557.


Assuntos
Diabetes Mellitus Tipo 1 , Serviços de Saúde Materna , Gravidez em Diabéticas , Feminino , Gravidez , Humanos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Gestantes , Insulina , Gravidez em Diabéticas/terapia
10.
N Engl J Med ; 389(17): 1566-1578, 2023 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-37796241

RESUMO

BACKGROUND: Hybrid closed-loop insulin therapy has shown promise for management of type 1 diabetes during pregnancy; however, its efficacy is unclear. METHODS: In this multicenter, controlled trial, we randomly assigned pregnant women with type 1 diabetes and a glycated hemoglobin level of at least 6.5% at nine sites in the United Kingdom to receive standard insulin therapy or hybrid closed-loop therapy, with both groups using continuous glucose monitoring. The primary outcome was the percentage of time in the pregnancy-specific target glucose range (63 to 140 mg per deciliter [3.5 to 7.8 mmol per liter]) as measured by continuous glucose monitoring from 16 weeks' gestation until delivery. Analyses were performed according to the intention-to-treat principle. Key secondary outcomes were the percentage of time spent in a hyperglycemic state (glucose level >140 mg per deciliter), overnight time in the target range, the glycated hemoglobin level, and safety events. RESULTS: A total of 124 participants with a mean (±SD) age of 31.1±5.3 years and a mean baseline glycated hemoglobin level of 7.7±1.2% underwent randomization. The mean percentage of time that the maternal glucose level was in the target range was 68.2±10.5% in the closed-loop group and 55.6±12.5% in the standard-care group (mean adjusted difference, 10.5 percentage points; 95% confidence interval [CI], 7.0 to 14.0; P<0.001). Results for the secondary outcomes were consistent with those of the primary outcome; participants in the closed-loop group spent less time in a hyperglycemic state than those in the standard-care group (difference, -10.2 percentage points; 95% CI, -13.8 to -6.6); had more overnight time in the target range (difference, 12.3 percentage points; 95% CI, 8.3 to 16.2), and had lower glycated hemoglobin levels (difference, -0.31 percentage points; 95% CI, -0.50 to -0.12). Little time was spent in a hypoglycemic state. No unanticipated safety problems associated with the use of closed-loop therapy during pregnancy occurred (6 instances of severe hypoglycemia, vs. 5 in the standard-care group; 1 instance of diabetic ketoacidosis in each group; and 12 device-related adverse events in the closed-loop group, 7 related to closed-loop therapy). CONCLUSIONS: Hybrid closed-loop therapy significantly improved maternal glycemic control during pregnancy complicated by type 1 diabetes. (Funded by the Efficacy and Mechanism Evaluation Program; AiDAPT ISRCTN Registry number, ISRCTN56898625.).


Assuntos
Glicemia , Diabetes Mellitus Tipo 1 , Hipoglicemiantes , Sistemas de Infusão de Insulina , Insulina , Gravidez em Diabéticas , Adulto , Feminino , Humanos , Gravidez , Glicemia/análise , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/complicações , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hemoglobinas Glicadas/análise , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/efeitos adversos , Hipoglicemiantes/uso terapêutico , Insulina/administração & dosagem , Insulina/efeitos adversos , Insulina/uso terapêutico , Sistemas de Infusão de Insulina/efeitos adversos , Gravidez em Diabéticas/sangue , Gravidez em Diabéticas/tratamento farmacológico , Resultado do Tratamento
11.
Diabetes Care ; 46(11): 1916-1922, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37616583

RESUMO

OBJECTIVE: We evaluated the safety and efficacy of fully closed-loop with ultrarapid insulin lispro in adults with type 1 diabetes and suboptimal glycemic control compared with insulin pump therapy with continuous glucose monitoring (CGM). RESEARCH DESIGN AND METHODS: This single-center, randomized, crossover study enrolled 26 adults with type 1 diabetes using insulin pump therapy with suboptimal glycemic control (mean ± SD, age 41 ± 12 years, HbA1c 9.2 ± 1.1% [77 ± 12 mmol/mol]). Participants underwent two 8-week periods of unrestricted living to compare fully closed-loop with ultrarapid insulin lispro (CamAPS HX system) with insulin pump therapy with CGM in random order. RESULTS: In an intention-to-treat analysis, the proportion of time glucose was in range (primary end point 3.9-10.0 mmol/L) was higher during closed-loop than during pump with CGM (mean ± SD 50.0 ± 9.6% vs. 36.2 ± 12.2%, mean difference 13.2 percentage points [95% CI 9.5, 16.9], P < 0.001). Time with glucose >10.0 mmol/L and mean glucose were lower during closed-loop than during pump with CGM (mean ± SD time >10.0 mmol/L: 49.0 ± 9.9 vs. 62.9 ± 12.6%, mean difference -13.3 percentage points [95% CI -17.2, -9.5], P < 0.001; mean ± SD glucose 10.7 ± 1.1 vs. 12.0 ± 1.6 mmol/L, mean difference -1.2 mmol/L [95% CI -1.8, -0.7], P < 0.001). The proportion of time with glucose <3.9 mmol/L was similar between periods (median [interquartile range (IQR)] closed-loop 0.88% [0.51-1.55] vs. pump with CGM 0.64% [0.28-1.10], P = 0.102). Total daily insulin requirements did not differ (median [IQR] closed-loop 51.9 units/day [35.7-91.2] vs. pump with CGM 50.7 units/day [34.0-70.0], P = 0.704). No severe hypoglycemia or ketoacidosis occurred. CONCLUSIONS: Fully closed-loop insulin delivery with CamAPS HX improved glucose control compared with insulin pump therapy with CGM in adults with type 1 diabetes and suboptimal glycemic control.


Assuntos
Diabetes Mellitus Tipo 1 , Humanos , Adulto , Pessoa de Meia-Idade , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Glicemia , Estudos Cross-Over , Automonitorização da Glicemia , Insulina Lispro/uso terapêutico , Resultado do Tratamento , Sistemas de Infusão de Insulina , Insulina Regular Humana/uso terapêutico
12.
J Diabetes Sci Technol ; : 19322968231187915, 2023 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-37503893

RESUMO

We evaluated the performance of the interoperable Cambridge hybrid closed-loop app with FreeStyle Libre 3 glucose sensor, and YpsoPump insulin pump in a real-world setting. Data from 100 users (63 adults [mean ± SD age 41.9 ± 14.0 years], 15 children [8.6 ± 5.2 years)] and 22 users of unreported age) for a period of 28 days were analyzed. Time in range (3.91- 10.0mmol/L) was 72.6 ± 11.1% overall. Time below range (<3.9mmol/L) was 3.1% (1.4-5.1) (median [interquartile range]). Auto-mode was active for 95.8% (91.8-97.9) of time. This real-world analysis suggests that the performance of Cambridge hybrid closed-loop app with this glucose sensor is comparable to other commercially available hybrid closed-loop systems.

13.
J Diabetes Sci Technol ; : 19322968231185348, 2023 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-37421250

RESUMO

BACKGROUND: We analyzed real-world evidence to assess the performance of the mylife CamAPS FX hybrid closed-loop system. METHODS: Users from 15 countries across different age groups who used the system between May 9, 2022, and December 3, 2022, and who had ≥30 days of continuous glucose monitor data, and ≥30% of closed-loop usage were included in the current analysis (N = 1805). RESULTS: Time in range (3.9-10 mmol/L) was 72.6 ± 11.5% (mean ± SD) for all users and increased by age from 66.9 ± 11.7% for users ≤6 years old to 81.8 ± 8.7% for users ≥65 years. Time spent in hypoglycemia (<3.9 mmol/L) was 2.3% [1.3, 3.6] (median [interquartile range]). Mean glucose and glucose management indicator were 8.4 ± 1.1 mmol/L and 6.9%, respectively. Time using closed-loop was high at 94.7% [90.0, 96.9]. CONCLUSIONS: Glycemic outcomes from the present real-world evidence are comparable to results obtained from previous randomized controlled studies and confirm the efficacy of this hybrid closed-loop system in real-world settings.

15.
Endocr Connect ; 12(8)2023 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-37289734

RESUMO

Automated insulin delivery systems, also known as closed-loop or 'artificial pancreas' systems, are transforming the management of type 1 diabetes. These systems consist of an algorithm which responds to real-time glucose sensor levels by automatically modulating insulin delivery through an insulin pump. We review the rapidly changing landscape of automated insulin-delivery systems over recent decades, from initial prototypes to the different hybrid closed-loop systems commercially available today. We discuss the growing body of clinical trials and real-world evidence demonstrating their glycaemic and psychosocial benefits. We also address future directions in automated insulin delivery such as dual-hormone systems and adjunct therapy as well as the challenges around ensuring equitable access to closed-loop technology.

16.
Diabetes Technol Ther ; 25(7): 485-491, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37229591

RESUMO

Objective: We aimed to assess whether percentage of time spent in hypoglycemia during closed-loop insulin delivery differs by age group and time of day. Methods: We retrospectively analyzed data from hybrid closed-loop studies involving young children (2-7 years), children and adolescents (8-18 years), adults (19-59 years), and older adults (≥60 years) with type 1 diabetes. Main outcome was time spent in hypoglycemia <3.9 mmol/L (<70 mg/dL). Eight weeks of data for 88 participants were analyzed. Results: Median time spent in hypoglycemia over the 24-h period was highest in children and adolescents (4.4% [interquartile range 2.4-5.0]) and very young children (4.0% [3.4-5.2]), followed by adults (2.7% [1.7-4.0]), and older adults (1.8% [1.2-2.2]); P < 0.001 for difference between age groups. Time spent in hypoglycemia during nighttime (midnight-05:59) was lower than during daytime (06:00-23:59) across all age groups. Conclusion: Time in hypoglycemia was highest in the pediatric age group during closed-loop insulin delivery. Hypoglycemia burden was lowest overnight across all age groups.


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Adolescente , Idoso , Criança , Pré-Escolar , Humanos , Glicemia , Estudos Cross-Over , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemia/induzido quimicamente , Hipoglicemia/tratamento farmacológico , Hipoglicemiantes/uso terapêutico , Insulina/efeitos adversos , Sistemas de Infusão de Insulina , Insulina Regular Humana/uso terapêutico , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem , Adulto , Pessoa de Meia-Idade
17.
BMJ Open ; 13(4): e070672, 2023 04 11.
Artigo em Inglês | MEDLINE | ID: mdl-37041065

RESUMO

INTRODUCTION: Medical devices, including high-risk medical devices, have greatly contributed to recent improvements in the management of diabetes. However, the clinical evidence that is submitted for regulatory approval is not transparent, and thus a comprehensive summary of the evidence for high-risk devices approved for managing diabetes in Europe is lacking. In the framework of the Coordinating Research and Evidence for Medical Devices group, we will, therefore, perform a systematic review and meta-analysis, which will evaluate the efficacy, safety and usability of high-risk medical devices for the management of diabetes. METHOD AND ANALYSIS: This study has been reported according to the guidelines of the Preferred Reporting Items for Systematic Review and Meta-Analysis Protocols. We will search Embase (Elsevier), Medline All (Ovid), Cochrane Library (Wiley), Science Citation Index Expanded and Emerging Sources Citation Index (Web of Science) to identify interventional and observational studies that evaluate the efficacy and/or safety and/or usability of high-risk medical devices for the management of diabetes. No language or publication dates' limits will be applied. Animal studies will be excluded. In accordance with the Medical Device Regulation in European Union, high-risk medical devices are those in classes IIb and III. The following medical devices for diabetes management are considered as having a high risk: implantable continuous glucose monitoring systems, implantable pumps and automated insulin delivery devices. Selection of studies, data extraction and quality of evidence assessment will be performed independently by two researchers. Sensitivity analysis will be performed to identify and explain potential heterogeneity. ETHICS AND DISSEMINATION: No ethical approval is needed for this systematic review, as it is based in already published data. Our findings will be published in a peer-reviewed journal. PROSPERO REGISTRATION NUMBER: CRD42022366871.


Assuntos
Automonitorização da Glicemia , Diabetes Mellitus Tipo 2 , Humanos , Glicemia , Revisões Sistemáticas como Assunto , Metanálise como Assunto
19.
Diabet Med ; 40(6): e15092, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36947090

RESUMO

AIMS: Fully closed-loop insulin delivery has been shown in clinical trials to be safe and improve glucose control compared with standard insulin therapy in the inpatient setting. We investigated the feasibility of implementing the approved CamAPS HX fully closed-loop system in a hospital setting. METHODS: This implementation project was conducted in a large teaching hospital in Cambridge, UK. Healthcare professional training was multimodal including face-to-face workshops, online learning modules and supported by standard operating procedures. Set-up and maintenance of closed-loop devices were undertaken by the inpatient diabetes team. Selection of suitable patients was multidisciplinary and prioritised those with more challenging diabetes management. Demographic and clinical data were collected from electronic health records and diabetes data management platforms. RESULTS: In the 12 months since the closed-loop system was implemented, 32 inpatients (mean ± SD age 61 ± 16 years, 8 females, 24 males) used closed-loop insulin delivery during their admission, across medical and surgical wards in the hospital with a total of 555 days of closed-loop glucose control (median [IQR]: 14 [6, 22] days per inpatient). The time spent in target glucose range 3.9-10.0 mmol/L was 53.3 ± 18.3%. Mean glucose was 10.7 ± 1.9 mmol/L with 46.0 ± 18.2% of time spent with glucose >10.0 mmol/L. Time spent with sensor glucose below 3.9 mmol/L was low (median [IQR]: 0.38 [0.00, 0.85]). There were no episodes of severe hypoglycaemia or diabetic ketoacidosis during closed-loop use. CONCLUSIONS: We have demonstrated that the fully closed-loop system can be safely and effectively implemented by a diabetes outreach team in complex medical and surgical inpatients with challenging glycaemic control.


Assuntos
Diabetes Mellitus Tipo 1 , Insulina , Masculino , Feminino , Humanos , Pessoa de Meia-Idade , Idoso , Insulina/uso terapêutico , Glicemia , Hipoglicemiantes/uso terapêutico , Pacientes Internados , Diabetes Mellitus Tipo 1/tratamento farmacológico , Resultado do Tratamento , Sistemas de Infusão de Insulina , Estudos Cross-Over
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...